Digital Clamp Ground Earth Resistance Meter Tester 0.01-200Ω

Specification

Item model number ETCR2100A+
Style Digital
Power Source Battery Powered
Color Red, Black
Brand ETCR
Item Weight 1160 Grams
Batteries 4 AA batteries required.
Is Discontinued By Manufacturer No
Package Dimensions 13.86 x 8.66 x 4.25 inches; 2.56 Pounds
Manufacturer ETCR


8.66 inches x 13.86 inches x 4.25 inches. Weight: 3.0 grams
 

Item Description

     

  • 【Application】 ETCR2100A+ Clamp Earth Resistance Tester is widely used in the grounding resistance measurement of the power, meteorology, oilfield, construction and the industrial and electrical equipment. In the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use. The tester can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the ETCR series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance.
  • 【Measurement Range】The measuring range of ETCR2100A+ ground resistance meter is 0.010Ω-200Ω with resolution 0.001Ω. The clamp size is Φ32mm.
  • 【Resistance Measurement Principle 】The basic principle of ETCR in the measurement of resistance is to measure the loop resistance. The jaw part of the Meter is comprised of voltage coil and current coil. The voltage coil provides excitation signal .It will induce a potential E on the measured loop. Under the action of electric potential E will have a current in the circuit to be tested, the meter will measure E & I. The measured resistance R can be obtained by the formula R=E/I.
  • 【Important Notice】From the measuring principle, ETCR series Meter can only measure the loop resistance, the single-point grounding is not measured. However, users are able to use a testing line very near to the earth electrode of the grounding system to artificially create a loop for testing. For details, please read user manuals.
  • 【Standard Accessories 】Earth Tester*1, Test Ring*1, Meter Case*1, Manual /Warranty Card / Qualification Certificate

Product Description

Overview

ETCR2100A+ Clamp Earth Resistance Tester is our company's technology research and development team on technical quality of the pursuit of excellence, through continuous innovation to improve, upgrade with the old product. Its performance is mainly reflected in:

  • Breakthrough in self-test the boot a long time to waiting, start immediately into the test.
  • Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology.
  • Breakthrough the old product too heavy issues, more in line with characteristics of hand-held devices.
  • New design, panel operation with 6 buttons, better performance.
  • Increase sound and light alarm function, with "beep-beep-beep” alarm sound.
  • Increase the interference signal recognition indicator function, with "beep-beep-beep” indicator.
  • Measurement range: 0.01Ω-200Ω
  • Stored data 99 Units. Lower power consumption, Maximum operating current less than 50mA.

ETCR2100A+ Clamp Earth Resistance Tester is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment. In the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use. The tester can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the ETCR series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance.

Field Application

The application of machine room earth resistance measurement

  • The machine room of telecommunication system normally in the upper deck of the building. It is hard to use the meg-ohm meter to measure. However, ETCR Clamp meters are very convenient to test.

The application of substation earth resistance measurement

  • ETCR series clamp meter can use to test the situation of contact and connect of circuit. With the help of one test line, it can be used to test the connect situation of equipment in station and the grounding system.

The application of building lightning protection grounding system measurement

  • If the earth poles of the building are independent of each other, the earth resistance can be measured by clamp to testing any of the earth poles, and the earth resistance can also be measured by clamp the building roof lightning arrester.When the measured value is less than the allowable value, the earth electrode is qualified.If the measurement value of the clamp meter is larger than the allowable value, please use ingle earth point method to measurement.

From the measuring principle, ETCR series Meter can only measure the loop resistance, the single-point grounding is not measured. However, users are able to use a testing line very near to the earth electrode of the grounding system to artificially create a loop for testing. For details, please read user manuals.

ETCR2100A+ Ground Resistance Meter Technical Specifications

Function Ground resistance test, Loop resistance test
Resistance Range 0.010Ω-200Ω
Resolution 0.001Ω
Power Supply DC: 6V ( 4 PCS of LR6 Alkaline batteries)
Clamp Size Φ32mm
LCD Size 4 Digits LCD display, Screen : 47mm(L)×28.5mm(W)
Accuracy ±1%rdg ± 0.01Ω
Data Storage 99 sets
Auto Power-Off Automatically power off after 5 minutes without any operate
Power Consumption ≤50mA, Continuously working for 30 hours
Working Environment -20℃~55℃ 20%rh~80%rh
Store Environment -20℃~60℃; below 90%rh
Alarm Threshold Setting Range Resistance: 1Ω~199Ω
Audible and Visible Alarm "Beep-beep-beep” alarm sound, alarm symbol flashing, press AL key to turn on/off and setting
Interference Signal Recognitio "Beep-beep-beep” indicator,NOISE symbol blinking
Protection Level Double insulation
Structural Feature Clamp CT
Shift Automatic shift
External Magnetic Field <40A/m
External Electrical Field <1V/m
Single Measurement Time 0.5 second
Resistance Measure Frequency >1KHz
Measured Current Frequency 50/60Hz Automatic
Low Battery Voltage Indicator When the battery voltage is lower than 5.3V, the low battery voltage symbol is displayed
Storage Full Indication Storage data full of 99 sets, flashed display "MEM" symbol
Over Range Indication Exceed range indication “OLΩ”, “L0.01” or “OL A”
Tester Weight 1030g (with batteries)
Clamp Dimension 260mm×90mm×66mm
Add to Cart
Add to Cart
Add to Cart
Add to Cart
Add to Cart
Add to Cart
Customer Reviews
4.3 out of 5 stars
107
4.6 out of 5 stars
34
4.7 out of 5 stars
8
4.2 out of 5 stars
10
Price $165.00$165.00 $220.00$220.00 $365.00$365.00 $187.00$187.00 $297.00$297.00 $367.00$367.00
Clamp Size Φ32mm Φ32mm Φ32mm 65mm×32mm 65mm×32mm 65mm×32mm
Resistance Range 0.010Ω~200Ω 0.010Ω~1200Ω 0.010Ω~1200Ω 0.010Ω~200Ω 0.010Ω~1200Ω 0.010Ω~1200Ω
Current Range 0.00mA~20.0A 0.00mA~20.0A
Add to Cart
Add to Cart
Add to Cart
Add to Cart
Add to Cart
Add to Cart
Customer Reviews
Price $212.00$212.00 $171.00$171.00 $353.00$353.00 $167.00$167.00 $216.00$216.00 $607.52$607.52
Clamp Size 55mmX32mm 55mmX32mm 55mmX32mm 55X32mm 55X32mm 65mm×32mm
Resistance Range 0.010Ω-1000Ω 0.010Ω-200Ω 0.010Ω-1000Ω 0.01-500Ω 0.01-500Ω 0.01Ω-1500Ω
Current Range 0.00mA -30.0A 0-20A 0.00mA~40.0A
Add to Cart
Add to Cart
Add to Cart
Add to Cart
Customer Reviews
5.0 out of 5 stars
1
Price $163.99$163.99 $217.00$217.00 $365.00$365.00 $216.00$216.00
Clamp Size Φ32mm Φ32mm Φ32mm 65mm×32mm
Resistance Range 0.010Ω~200Ω 0.010Ω~1200Ω 0.010Ω~1200Ω 0.010Ω~200Ω
Current Range 0.00mA~20.0A

 

 

 

 

 


    Return Policy 

• We guarantee against any defective or misrepresented products. The original shipping label must be sent back to us to validate the return. A full refund can only be issued during the first 30 days upon receipt of the product.
• Returns will be voided if the product is mishandled or physical damaged by customer.
• Buyer will be responsible for all kind of return shipping/shipment to the seller for resolving the problem.
• Returns made for all non-defective, undamaged products are subject to a 15% restocking fee. Shipping and handling fees are absolutely non-refundable. If an item is returned to us due to an address issue, we do charge a reshipping fee to reship. If you would like a refund, there will be a 15% restocking fee applied.
• All returned products need to be assigned an RMA # (Return Merchandise Authorization #) prior to return. Please contact us through's messaging system to obtain an RMA# for the return. Any returned product without an RMA # on package will not be accepted or processed.
• Please contact us before returning.

      Feedback

• We appreciate your feedback and our system will automatically leave feedback for you after bid ends.
• Please contact us through message center if you have any problems, we will always try our best for 100% customer satisfaction.