Digital Clamp Ground Earth Resistance Meter Tester 0.01-200Ω
Specification
Item model number | ETCR2100A+ |
Style | Digital |
Power Source | Battery Powered |
Color | Red, Black |
Brand | ETCR |
Item Weight | 1160 Grams |
Batteries | 4 AA batteries required. |
Is Discontinued By Manufacturer | No |
Package Dimensions | 13.86 x 8.66 x 4.25 inches; 2.56 Pounds |
Manufacturer | ETCR |
8.66 inches x 13.86 inches x 4.25 inches. Weight: 3.0 grams
Item Description
- 【Application】 ETCR2100A+ Clamp Earth Resistance Tester is widely used in the grounding resistance measurement of the power, meteorology, oilfield, construction and the industrial and electrical equipment. In the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use. The tester can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the ETCR series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance.
- 【Measurement Range】The measuring range of ETCR2100A+ ground resistance meter is 0.010Ω-200Ω with resolution 0.001Ω. The clamp size is Φ32mm.
- 【Resistance Measurement Principle 】The basic principle of ETCR in the measurement of resistance is to measure the loop resistance. The jaw part of the Meter is comprised of voltage coil and current coil. The voltage coil provides excitation signal .It will induce a potential E on the measured loop. Under the action of electric potential E will have a current in the circuit to be tested, the meter will measure E & I. The measured resistance R can be obtained by the formula R=E/I.
- 【Important Notice】From the measuring principle, ETCR series Meter can only measure the loop resistance, the single-point grounding is not measured. However, users are able to use a testing line very near to the earth electrode of the grounding system to artificially create a loop for testing. For details, please read user manuals.
- 【Standard Accessories 】Earth Tester*1, Test Ring*1, Meter Case*1, Manual /Warranty Card / Qualification Certificate
Product Description
Overview
ETCR2100A+ Clamp Earth Resistance Tester is our company's technology research and development team on technical quality of the pursuit of excellence, through continuous innovation to improve, upgrade with the old product. Its performance is mainly reflected in:
- Breakthrough in self-test the boot a long time to waiting, start immediately into the test.
- Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology.
- Breakthrough the old product too heavy issues, more in line with characteristics of hand-held devices.
- New design, panel operation with 6 buttons, better performance.
- Increase sound and light alarm function, with "beep-beep-beep” alarm sound.
- Increase the interference signal recognition indicator function, with "beep-beep-beep” indicator.
- Measurement range: 0.01Ω-200Ω
- Stored data 99 Units. Lower power consumption, Maximum operating current less than 50mA.
ETCR2100A+ Clamp Earth Resistance Tester is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment. In the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use. The tester can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the ETCR series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance.
Field Application
The application of machine room earth resistance measurement
- The machine room of telecommunication system normally in the upper deck of the building. It is hard to use the meg-ohm meter to measure. However, ETCR Clamp meters are very convenient to test.
The application of substation earth resistance measurement
- ETCR series clamp meter can use to test the situation of contact and connect of circuit. With the help of one test line, it can be used to test the connect situation of equipment in station and the grounding system.
The application of building lightning protection grounding system measurement
- If the earth poles of the building are independent of each other, the earth resistance can be measured by clamp to testing any of the earth poles, and the earth resistance can also be measured by clamp the building roof lightning arrester.When the measured value is less than the allowable value, the earth electrode is qualified.If the measurement value of the clamp meter is larger than the allowable value, please use ingle earth point method to measurement.
From the measuring principle, ETCR series Meter can only measure the loop resistance, the single-point grounding is not measured. However, users are able to use a testing line very near to the earth electrode of the grounding system to artificially create a loop for testing. For details, please read user manuals.
ETCR2100A+ Ground Resistance Meter Technical Specifications
Function | Ground resistance test, Loop resistance test |
Resistance Range | 0.010Ω-200Ω |
Resolution | 0.001Ω |
Power Supply | DC: 6V ( 4 PCS of LR6 Alkaline batteries) |
Clamp Size | Φ32mm |
LCD Size | 4 Digits LCD display, Screen : 47mm(L)×28.5mm(W) |
Accuracy | ±1%rdg ± 0.01Ω |
Data Storage | 99 sets |
Auto Power-Off | Automatically power off after 5 minutes without any operate |
Power Consumption | ≤50mA, Continuously working for 30 hours |
Working Environment | -20℃~55℃ 20%rh~80%rh |
Store Environment | -20℃~60℃; below 90%rh |
Alarm Threshold Setting Range | Resistance: 1Ω~199Ω |
Audible and Visible Alarm | "Beep-beep-beep” alarm sound, alarm symbol flashing, press AL key to turn on/off and setting |
Interference Signal Recognitio | "Beep-beep-beep” indicator,NOISE symbol blinking |
Protection Level | Double insulation |
Structural Feature | Clamp CT |
Shift | Automatic shift |
External Magnetic Field | <40A/m |
External Electrical Field | <1V/m |
Single Measurement Time | 0.5 second |
Resistance Measure Frequency | >1KHz |
Measured Current Frequency | 50/60Hz Automatic |
Low Battery Voltage Indicator | When the battery voltage is lower than 5.3V, the low battery voltage symbol is displayed |
Storage Full Indication | Storage data full of 99 sets, flashed display "MEM" symbol |
Over Range Indication | Exceed range indication “OLΩ”, “L0.01” or “OL A” |
Tester Weight | 1030g (with batteries) |
Clamp Dimension | 260mm×90mm×66mm |
Add to Cart | Add to Cart | Add to Cart | Add to Cart | Add to Cart | Add to Cart | |
---|---|---|---|---|---|---|
Customer Reviews | 4.3 out of 5 stars 107 | 4.6 out of 5 stars 34 | 4.7 out of 5 stars 8 | 4.2 out of 5 stars 10 | — | — |
Price | $165.00$165.00 | $220.00$220.00 | $365.00$365.00 | $187.00$187.00 | $297.00$297.00 | $367.00$367.00 |
Clamp Size | Φ32mm | Φ32mm | Φ32mm | 65mm×32mm | 65mm×32mm | 65mm×32mm |
Resistance Range | 0.010Ω~200Ω | 0.010Ω~1200Ω | 0.010Ω~1200Ω | 0.010Ω~200Ω | 0.010Ω~1200Ω | 0.010Ω~1200Ω |
Current Range | ✘ | ✘ | 0.00mA~20.0A | ✘ | ✘ | 0.00mA~20.0A |
Add to Cart | Add to Cart | Add to Cart | Add to Cart | Add to Cart | Add to Cart | |
---|---|---|---|---|---|---|
Customer Reviews | — | — | — | — | — | — |
Price | $212.00$212.00 | $171.00$171.00 | $353.00$353.00 | $167.00$167.00 | $216.00$216.00 | $607.52$607.52 |
Clamp Size | 55mmX32mm | 55mmX32mm | 55mmX32mm | 55X32mm | 55X32mm | 65mm×32mm |
Resistance Range | 0.010Ω-1000Ω | 0.010Ω-200Ω | 0.010Ω-1000Ω | 0.01-500Ω | 0.01-500Ω | 0.01Ω-1500Ω |
Current Range | ✘ | ✘ | 0.00mA -30.0A | ✘ | 0-20A | 0.00mA~40.0A |
Add to Cart | Add to Cart | Add to Cart | Add to Cart | |
---|---|---|---|---|
Customer Reviews | 5.0 out of 5 stars 1 | — | — | — |
Price | $163.99$163.99 | $217.00$217.00 | $365.00$365.00 | $216.00$216.00 |
Clamp Size | Φ32mm | Φ32mm | Φ32mm | 65mm×32mm |
Resistance Range | 0.010Ω~200Ω | 0.010Ω~1200Ω | 0.010Ω~1200Ω | 0.010Ω~200Ω |
Current Range | ✘ | ✘ | 0.00mA~20.0A | ✘ |
Return Policy
• We guarantee against any defective or misrepresented products. The original shipping label must be sent back to us to validate the return. A full refund can only be issued during the first 30 days upon receipt of the product.
• Returns will be voided if the product is mishandled or physical damaged by customer.
• Buyer will be responsible for all kind of return shipping/shipment to the seller for resolving the problem.
• Returns made for all non-defective, undamaged products are subject to a 15% restocking fee. Shipping and handling fees are absolutely non-refundable. If an item is returned to us due to an address issue, we do charge a reshipping fee to reship. If you would like a refund, there will be a 15% restocking fee applied.
• All returned products need to be assigned an RMA # (Return Merchandise Authorization #) prior to return. Please contact us through's messaging system to obtain an RMA# for the return. Any returned product without an RMA # on package will not be accepted or processed.
• Please contact us before returning.
Feedback
• We appreciate your feedback and our system will automatically leave feedback for you after bid ends.
• Please contact us through message center if you have any problems, we will always try our best for 100% customer satisfaction.