This EMCO Engineering TMP-910-2F150 Turbo-Bar Insertion Turbine Flow Meter is in great condition and is guaranteed to be fully functional. This item came from large pharmaceutical company that had surplus equipment. We urge customers to view all photos as they show overall condition, included accessories, and useful information. We will be happy to provide additional information as well as photos so please feel free to contact us with any questions.
EMCO's Turbo-Bar™ flow meter provides significant cost savings for line sizes from 3 to 80" without compromising performance. With high accuracy, wide turndown, and a unique low-mass rotor design without welded joints, the Turbo-Bar™ flow meter gives you the benefit of over 30 years of practical experience. The Turbo-Bar™ measures liquids or gases, including steam, for pipe sizes from 3 to 80".
|
Specifications
Performance Specifications | ||
Accuracy (linear ranges) |
L1, G1-G5 | ±1.0% of flow rate |
G6 Rotor | ±3.0% of flow rate | |
Repeatability | ± 0.25% of flow rate |
Operating Specifications | ||
Fluid types | Liquid, gas, or steam | |
Measurable flow velocities | ||
Process measurement | TMP-600/60S | 125 psi (8.62 barg) Line Sizes 3-20" |
TMP-700 | 5000 psi (1345 barg) Line Sizes 3-80" | |
TMP-910/960 | According to flange rating, up to 1500 psi Line Sizes 3-80" | |
Process temperature limit | TMP-600/60S | 400°F (204°C) max |
TMP-700 | 600°F (316°C) max | |
TMP-910/960 | 750°F (400°C) max | |
Ambient temperature limit | EZ-Logic™ electronics | 32 to 140°F (0 to 60°C) |
All other electronics | -20 to 140 °F (-40 to 60 °C) | |
Ambient humidity limit | Up to 100% RH non-condensing | |
Power requirements | EZ-Logic™ electronics | 18 to 40 VDC, 24 VDC nominal |
All other electronics | 15 to 40 VDC, 24 VDC nominal | |
Output signals | EZ-Logic™ electronics | 4 to 20 mA analog and frequency/pulse outputs and local rate and total display |